RIGOL 2 Command System
2-546 DS2000 Programming Guide
2-546
:TRIGger:USB:MLEVel
Syntax
:TRIGger:USB:MLEVel <level>
:TRIGger:USB:MLEVel?
Description
Set the trigger level of the D- data line in USB trigger and the unit is the same with
the current amplitude unit.
Query the current trigger level of the D- data line in USB trigger.
Parameter
Name Type Range Default
<level> Real
± 5 × VerticalScale from the screen center -
OFFSet
0
Note:
For the VerticalScale, refer to the
:CHANnel<n>:SCALe command.
For the OFFSet, refer to the
:CHANNel<n>:OFFSet command.
Return Format
The query returns the trigger level in scientific notation.
Example
:TRIGger:USB:MLEVel 0.16
The query returns 1.600000e-01.