2 Command System RIGOL
DS2000 Programming Guide
2-141
:CURSor:MANual:TYPE
Syntax
:CURSor:MANual:TYPE <type>
:CURSor:MANual:TYPE?
Description
Select the cursor type of manual cursor measurement.
Query the current cursor type of manual cursor measurement.
Parameter
Name Type Range Default
<type> Discrete {TIME|AMPLitude} TIME
Explanation
TIME: select X cursors which are usually used to measure time parameters.
AMPLitude: select Y cursors which are usually used to measure voltage parameters.
Return Format
The query returns TIME or AMPL.
Example
:CURSor:MANual:TYPE AMPLitude
The query returns AMPL.