RIGOL 2 Command System
2-34 DS2000 Programming Guide
2-34
:BUS<n>:PARallel:CLK
Syntax
:BUS<n>:PARallel:CLK <sour>
:BUS<n>:PARallel:CLK?
Description
Set the clock channel source of parallel decoding on bus 1 or 2.
Query the current clock channel source of parallel decoding on bus 1 or 2.
Parameter
Name Type Range Default
<n> Discrete {1|2} --
<sour> Discrete {CHANnel1|CHANnel2|OFF} OFF
Explanation
When OFF is selected, no clock channel is set and the oscilloscope samples data once
the channel data jumps. At this point, the edge set by the
:BUS<n>:PARallel:SLOPe
command can be ignored.
Return Format
The query returns CHAN1, CHAN2 or OFF.
Example
:BUS1:PARallel:CLK CHANnel2
The query returns CHAN2.