Rigol DS2000 Series Dokumentacja Strona 411

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 616
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 410
2 Command System RIGOL
DS2000 Programming Guide
2-393
:MEASure:VTOP?
Syntax
:MEASure:VTOP? <chan>
Description
Query the top value of the selected waveform.
Parameter
Name Type Range Default
<chan> Discrete {CHANnel1|CHANnel2} CHANnel2
Explanation
The unit depends on the unit of the source channel (refer to
the
:CHANnel<n>:UNITs command).
Return Format
The query returns the measurement result in scientific notation.
Example
:MEASure:VTOP? CHANnel1
The query returns 1.920000e+00.
You can use the following commands to query the statistic maximum, minimum,
current value, average and standard deviation of the top values of the selected
waveform. Sending the following commands will enable the statistic function
automatically.
:MEASure:VTOP:SMAXimum?
:MEASure:VTOP:SMINimum?
:MEASure:VTOP:SCURrent?
:MEASure:VTOP:SAVerage?
:MEASure:VTOP:SDEViation?
Przeglądanie stron 410
1 2 ... 406 407 408 409 410 411 412 413 414 415 416 ... 615 616

Komentarze do niniejszej Instrukcji

Brak uwag