2 Command System RIGOL
DS2000 Programming Guide
2-35
:BUS<n>:PARallel:SLOPe
Syntax
:BUS<n>:PARallel:SLOPe <pos>
:BUS<n>:PARallel:SLOPe?
Description
Set the oscilloscope to sample the channel data on the rising edge, falling edge or
rising&falling edges of the clock.
Query on which kind of edge of the clock the oscilloscope samples the data channel.
Parameter
Name Type Range Default
<n> Discrete {1|2} --
<pos> Discrete {POSitive|NEGative|BOTH} POSitive
Explanation
When no clock channel is set (refer to the
:BUS<n>:PARallel:CLK command), the
oscilloscope samples data once the channel data jumps and the edge set by this
command can be ignored.
Return Format
The query returns POS, NEG or BOTH.
Example
:BUS1:PARallel:SLOPe NEGative
The query returns NEG.