REL
Function:
The command enables the REL mode and sets the value shown on the main
display as its value.
17. RELCLR
Command Format:
RELCLR
Function:
The command disables the REL mode and backs to Range mode. The range is the
one before REL.
18. RELSET
Command Format:
RELSET<relative base>
RELSET?
Function:
RELSET<relative base>: Enable the REL mode and set <relative base> as its
value.
RELSET?: Query the current <relative base>. If the REL mode is not enables, an
execution error may be occur.
Explanation:
<relative base> could be a signed integer, a signed real number without
exponent, or a signed real number with exponent. If <relative base>exceeds the
range, an execution error may be occur.
Return Format:
The query returns the <relative base> in REL mode.