2 Command System RIGOL
MSO2000A/DS2000A Programming Guide
2-81
:CURSor Commands
:CURSor:MODE
:CURSor:MANual
:CURSor:TRACk
:CURSor:MODE
Syntax
:CURSor:MODE <mode>
:CURSor:MODE?
Description
Set or query the cursor measurement mode.
Parameter
Name Type Range Default
<mode> Discrete {OFF|MANual|TRACk|AUTO|XY} OFF
Explanation
OFF: disable the cursor measurement.
MANual: enable the manual measurement with cursor.
TRACk: enable the track measurement with cursor.
AUTO: enable the auto measurement with cursor.
XY: enable the X-Y cursor measurement. This mode is only valid when the horizontal time base mode
is X-Y (please refer to the
:TIMebase:MODE command).
Return Format
The query returns OFF, MAN, TRAC, AUTO or XY.