RIGOL 2 Command System
2-70 MSO2000A/DS2000A Programming Guide
:CALCulate:ADVanced:VSCale
Syntax
:CALCulate:ADVanced:VSCale <numeric_value>
:CALCulate:ADVanced:VSCale?
Description
Set or query the vertical scale of the advanced operation result. The unit is related to the advanced
operation expression.
Parameter
Name Type Range Default
<numeric_value> Real
The default range is from 0.02 to 500.
The actual range is related to the advanced
operation expression.
2V
Note: For the advanced operation expression, refer to the :CALCulate:ADVanced:EXPRession command. The
expression might include CH1 or CH2; at this point, the actual range of <numeric_value> ia also related to the
channel vertical scale. For the channel vertical scale, refer to the
:CHANnel<n>:SCALe command.
Return Format
The query returns the vertical scale of the advanced operation result in scientific notation.
:CALCulate:ADVanced:VOFFset
Syntax
:CALCulate:ADVanced:VOFFset <offs>
:CALCulate:ADVanced:VOFFset?
Description
Set or query the vertical offset of the advanced operation result. The unit is related to the advanced
operation expression.
Parameter
Name Type Range Default
<offs> Real -40×VScale to 40×VScale 0
Note: For the VScale (the vertical scale of MATH), refer to the :CALCulate:ADVanced:VSCale command.
Return Format
The query returns the vertical offset of the advanced operation result in scientific notation.