2 Command System RIGOL
MSO2000A/DS2000A Programming Guide
2-279
:TRIGger:CAN:BUSer
Syntax
:TRIGger:CAN:BUSer <user baud>
:TRIGger:CAN:BUSer?
Description
Set or query the user-defined signal rate of CAN trigger. The unit is b/s.
Parameter
Name Type Range Default
<user baud> Integer 10000 to 1000000 50000
Return Format
The query returns the user-defined signal rate of CAN trigger in integer.
:TRIGger:CAN:SOURce
Syntax
:TRIGger:CAN:SOURce <source>
:TRIGger:CAN:SOURce?
Description
Set or query the trigger source of CAN trigger.
Parameter
Name Type Range Default
<source> Discrete
{D0|D1|D2|D3|D4|D5|D6|D7|D8|D9|D10|
D11|D12|D13|D14|D15|CHANnel1|CHANnel2}
CHANnel1
Return Format
The query returns D0, D1, D2, D3, D4, D5, D6, D7, D8, D9, D10, D11, D12, D13, D14, D15, CHAN1 or
CHAN2.