Rigol DS1000Z Series Dokumentacja Strona 24

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 172
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 23
RIGOL Chapter 2 Command System
2-10 DS1000Z Programming Guide
:CHANnel<n>:OFFSet
Syntax :CHANnel<n>:OFFSet <offset>
:CHANnel<n>:OFFSet?
Description
Set or query the vertical offset of the specified channel. The default unit is V.
Parameter
Name
Type
Range
Default
<n> Discrete {1|2|3|4}
——
<offset> Real
Be dependent on the current vertical scale and
probe ratio. When the probe ratio is 1,
vertical scale500mV/div: -100V to +100V
vertical scale<500mV/div: -2V to +2V
0V
Return
Format
The query returns the vertical offset in scientific notation.
Example
:CHANnel1:OFFSet 0.01 /*Set the vertical offset of CH1 to 10mV*/
:CHANnel1:OFFSet? /*The query returns 1.000000e-02*/
:CHANnel<n>:RANGe
Syntax :CHANnel<n>:RANGe <range>
:CHANnel<n>:RANGe?
Description
Set or query the vertical range of the specified channel. The default unit is V.
Parameter
Name
Type
Range
Default
<n>
Discrete
{1|2|3|4}
——
<range> Real
Be dependent on the current vertical scale and
probe ratio. When the probe ratio is 1,
8mV to 80V
8V
Explanation This command indirectly modifies the vertical scale of the specified channel (vertical
range=8*vertical scale). The vertical scale can be set by the
:CHANnel<n>:SCALe
command.
Return
Format
The query returns the vertical range in scientific notation.
Example
:CHANnel1:RANGe 8 /*Set the vertical range of CH1 to 8V*/
:CHANnel1:RANGe? /*The query returns 8.000000e+00*/
Related
Command
:CHANnel<n>:SCALe
Przeglądanie stron 23
1 2 ... 19 20 21 22 23 24 25 26 27 28 29 ... 171 172

Komentarze do niniejszej Instrukcji

Brak uwag