RIGOL
Programming Guide for DS1000B Series
2-8
1. :KEY:LOCK
Command Format:
:KEY:LOCK{ ENABle | DISable }
Function:
The command enables and disables the function of Remote control on the keys
of front panel.
Query Format:
:KEY:LOCK?
Return Format:
The query returns ENABLE or DISABLE.
Example:
:KEY:LOCKENABle Enable remote control on the keys of front panel .
:KEY:LOCK? Return ENABLE.
2. :KEY:RUN
Command Format:
:KEY:RUN
Function:
This command controls the running state of the oscilloscope. The oscilloscope
will cutover between RUN and STOP when sending this command continually.
3. :KEY:AUTO
Command Format:
:KEY:AUTO
Function:
The command sets oscilloscope automatically to display the waveform to be
optimal condition.
4. :KEY:SINGLe
Command Format:
:KEY:SINGLe