Example:
:TRIG:ALT:PULS:HOLD 1 Setup the holdoff time as 1s.
:TRIG:ALT:PULS:HOLD? The query returns 1.000e+00.
17. :TRIGger:ALTernation<mode>:SENSitivity
Command Format:
:TRIGger:ALTernation<mode>:SENSitivity <count>
:TRIGger:ALTernation<mode>:SLOPe:SENSitivity?
Function Explanation:
The commands set and query the trigger sensitive. The <mode> could
be :EDGE, :PULSe, :SLOPe or :VIDEO. The range of <count> is 0.1div ~1div.
Returned Format:
The query returns the setting value of <count> in div.
Example:
:TRIG:ALT:EDGE:SENS 0.5 Setup the trigger sensitive as 0.5div.
:TRIG:ALT:EDGE:SLOP:SENS? The query returns 5.00e-01.