Programming Guide for DS1000/DS1000CA Series
2-56
3. Set the Pulse width trigger condition
This trigger type is used to catch pulses with certain pulse width requirement.
3.1 :TRIGger:PULSe:MODE
Command Format:
:TRIGger:PULSe:MODE<mod>
Explanation:
The command is to set the pulse condition; +Greater than (positive pulse width
greater than), +Less than (positive pulse width less than), + Equal (positive pulse
width equal to), -Greater than (negative pulse width greater than), -Less than
(negative pulse width less than) or Equal (negative pulse width eaqual to).
<mod> can be set to +GREaterthan, +LESSthan, +EQUal, -GREaterthan,
-LESSthan or -EQUal.
Query Format:
:TRIGger:PULSe:MODE?
Returned Format:
Query returns “+GREATER THAN, +LESS THAN, +EQUAL, -GREATER THAN,
-LESS THAN or -EQUAL. The double quotes are not returned.
Example:
:TRIGger:PULSe:MODE+GREATERTHAN
Set the pulse width condition as +GREATER THAN
:TRIGger:PULSe:MODE?
Query returns +GREATER THAN
3.2 :TRIGger:PULSe:WIDTh
Command Format:
:TRIGger:PULSe:WIDTh<wid>
Explanation:
The command is to set the pulse width from 20ns ~ 10s.