Rigol DS1000E series Podręcznik Użytkownika Strona 138

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 137
RIGOL
© 2008 RIGOL Technologies, Inc.
User’s Guide for DS1000E, DS1000D Series
3-8
Example 6: The application of the X-Y operation
Viewing Phase Changes through a Network
Theme: Connect the oscilloscope to monitor the input and output of the circuit and
capture the phase changes.
To view the input and output of the circuit in an X-Y display, do these steps:
1. From the probe menu set the attenuation to 10X. Set the switch to 10X on the
probes.
2. Connect the CH 1 probe to the input of the network, and connect the CH 2 probe
to the output.
3. If the channels are not displayed, press the CH1 and CH2 buttons.
4. Press the AUTO button
5. Adjust the vertical knob to display approximately the same amplitude
signals on each channel
6. Press the MENU in horizontal control area to display the menu
7. Press the Time Base soft button to select X-Y
The oscilloscope displays a Lissajous pattern representing the input and output
characteristics of the circuit
8. Adjust the vertical and knobs to a desirable
waveform display.
9. Apply the Ellipse method to observe the phase difference between the two
channels.
(See Figure 3-6)
Przeglądanie stron 137
1 2 ... 133 134 135 136 137 138 139 140 141 142 143 ... 161 162

Komentarze do niniejszej Instrukcji

Brak uwag