Chapter 2 Command System RIGOL
Programming Guide for DM3000
the form of scientific notation such as +3.13000000E+02.
6. :CALCulate:STATistic:STATe
:CALCulate:STATistic:STATe?
:CALCulate:STATistic:STATe {ON|OFF|1|0}
Turns on or off the statistic funtion.
The query returns ON if there is a statistic function enabled currently
such as MAX, MIN or Average, or returns OFF if all of the statistic
functions are disabled.
:CALCulate:NULL:STATe?
:CALCulate:NULL:STATe {ON|OFF|1|0}
Turns on or off the Null operation function.
The query returns ON or OFF.
8. :CALCulate:NULL:OFFSet
:CALCulate:NULL:OFFSet?
:CALCulate:NULL:OFFSet {
<range>
|MIN|MAX|DEF}
Sets the offset for Null operations.
The query returns the Null offset off the current measurement
function in the form of scientific notation.
The offset is allowed to reach the seventh decimal place.
Different measurements have different setting
ranges:
Setting the Null offset for DC voltage measurements to 10.2010031V:
:CALCulate:NULL:OFFSet 10.2010031
The query returns: +1.02010031e+01.