RIGOL
10
DSA1000A series Spectrum Analyzer
Features and Benets
9 kHz - 3 GHz Frequency Range
-148 dBm Displayed Average Noise Level (DANL)
-88 dBc/Hz@10 kHz Phase Noise (typ.)
Overall Amplitude accuracy <1.0 dB
10 Hz Minimum Resolution Bandwidth (RBW)
Standard with Preamplier
3 GHz Tracking Generator (option)
Breadth of measurement functions and automatic settings provide
ultimate exibility
8.5 inch widescreen display with clear, vivid, and easy to use graphical interface
Various interface options such as LAN\USB host, USB device,
VGA or GPIB (option)
Compact design with a weight of only 13.7 lbs
Key Specications
Bandwidths
Resolution Bandwidth (-3 dB)
RBW Uncertainty
Resolution Filter Shape Factor
(60 dB: 3 dB)
Video Bandwidth (-3 dB)
10 Hz to 1 MHz, in 1-3-10 sequence
< 5%, nominal
< 5, nominal
1 Hz to 3 MHz, in 1-3-10 sequence
20
to 30
DSA1030A
Frequency
Frequency Range
Frequency Resolution
10 MHz
<3 ppm/year
<3 ppm
Internal Frequency Reference
Reference Frequency
Aging Rate
Temperature Drift
9 kHz to 3 GHz
1 Hz
10 kHz
100 kHz
1 MHz
SSB phase noise
Carrier Offset
<-88 dBc/Hz, typical
<-100 dBc/Hz, typical
<-110 dBc/Hz, typical
Frequency
Amplitude
50 V
30 dBm (1W)
40 dBm (10W)
Note: when input level >33 dBm, the protection switch will be on.
Measurement Range
Range
Maximum rated input level
DC Voltage
CW RF Power
Max. Damage Level
DANL to +30 dBm
RF attenuation ≥ 20 dB
DANL (Preamplier Off)
100 kHz to 10 MHz
10 MHz to 2.5 GHz
2.5 GHz to 3 GHz
100 kHz to 1 MHz
1 MHz to 10 MHz
10 MHz to 2.5 GHz
2.5 GHz to 3 GHz
<-85 dBm-3 × (f/1 MHz)dB, typ. -125 dBm
<-127 dBm+3 × (f/1 GHz)dB, typ. -130 dBm
<-115 dBm
<-103 dBm
<-103 dBm-3 × (f/1 MHz)dB, typ. -143 dBm
<-145 dBm+3 × (f/1 GHz)dB, typ. -148 dBm
<-133 dBm
DANL (Preamplier On)
Displayed Average Noise Level (DANL)
0 dB RF Attenuation, RBW=VBW=10Hz, Sample Detector, Trace Average ≥ 50
95% condence level, S/N>20 dB,
RBW=VBW=1 kHz,
preamplier off,
10 dB RF attenuation,
-50 dBm<reference level<0,
10 MHz<fc<3 GHz,
20 ºC to 30 ºC
<1.0 dB, nominal
Level Measurement Uncertainty
Level Measurement Uncertainty
Note: typical fc = 500 MHz, RBW≤1 kHz, sample detector, and trace average≥50.