Rigol M300 Instrukcja Użytkownika Strona 10

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 89
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 9
RIGOL Chapter 1 Programming Overview
Programming Guide for DM3000
1-4
Parameter Type
1. MIN|MAX|DEF
Usually, MIN, MAX and DEF are used to represent the maximum, minimum and
default values of a parameter. For example, in the command
:MEASure:VOLTage:DC
{0|1|2|3|4|MIN|MAX|DEF},
MIN corresponds to 0, MAX corresponds to 4 and DEF corresponds to 2. For more
details, please refer to :MEASure:VOLTage:DC.
2. Consecutive Integer Parameter
The parameter can be any integer within the effective range. Please do not set
the parameter to a decimal; otherwise, error may occur. For example, in the
command ":SYSTem:DISPlay:BRIGht", the parameter can be any integer
within 0 and 255.
3. Consecutive Real Number Parameter
The parameter can be any value within the effective range according to the
precision requirement. For example, in the command
":CALCulate:NULL:OFFSet", the parameter can hold seven digits after the
decimal point.
4. Discrete Parameter
The parameter should be one of the values listed in the command. For example,
in the command ":MEASure:VOLTage:AC", the parameter can only be 0, 1, 2, 3
or 4.
5. Bool Parameter
The parameter can only be ON (1) or OFF (0). For example, in the command
:SYSTem:BEEPer:STATe, the parameter can only be ON (1) or OFF (0).
6. ASCII Character string
The parameter should be a combination of ASCII characters. For example, in the
command ":SYSTem:CLOCk:DATE, the parameter is a character string in date
format.
Przeglądanie stron 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 ... 88 89

Komentarze do niniejszej Instrukcji

Brak uwag